BiRa 2351
BiRa 2351
Data inputs must precede the strobe by at least 10 ns. The strobe signal must be a minimum of 10 ns wide. All inputs are active low (-12 to 36mA). An open input is a logic 0 level.
Set up the polling interval
Enabled channels will appear in the data read out list with the label that is specified in the dialog for that channel. If an event is triggered, each of the items in the read out list for each triggered channel will be read out.
Event Record
xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
^^^^ ^^^^ ^^^^ ^^-----------------------data id
^^ ^^^^ ^^^^ ^^^^ ^^^^-length in longs
xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx event count
xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
^ ^^^---------------------------crate
^ ^^^^---------------------card
if timestamp included the next two words follow, otherwise nothing. Check the length!
xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
^^^^ ^^^^ ^^^^ ^^^^ ^^^^ ^^^^ ^^^^ ^^^^-reference date (high part of double)
xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
^^^^ ^^^^ ^^^^ ^^^^ ^^^^ ^^^^ ^^^^ ^^^^-reference date (low part of double)
Reads the input register
Shows bit levels (Read Only)